Door closer – Clear lines


Door closer – Clear lines


Door closer with adjustable closing force:

The standards stipulate that the door closer size (closing force of the closer) must be selected

appropriate to the door width.

The next highest size must be selected if the structural (door height, door weight) or local

conditions (wind infl uence) makes this necessary.


The TS 4000 and variants covers several door closer sizes in one housing. These sizes can be

adjusted using an adjustment screw. The adjusted closing force is shown by a closing force indicator.

Cover caps for door closer For door closer TS 2000 V and TS 4000

cover caps are as follows available:

silver

_ dark bronze

_ white RAL 9016

_ polished brass

_ stainless steel

and further RAL colours on request.

TS 1000 C

Overhead door closer for single-leaf doors

Product features

_ Variable closing force in two sizes achieved by simply turning the link arm’s power shoe:

‘Weak’ (closing force size 2 to EN 1154) for leaf widths up to 850 mm

‘Strong’ (closing force size 3 to EN 1154) for leaf widths up to 950 mm

_ Increased closing force due to off set installation for leaf widths up to 1100 mm (size 4 to EN 1154)

_ Closing speed adjustable, as is hydraulic latching action

_ Option: with hold-open link arm allowing the closer to hold doors open between 700 and 150

Application range

_ For single-action doors up to 950 mm (1100 mm)

_ Can be used for right and left hand doors

without adjustment

_ For all common types of installation

Standard version/package

Overhead door closer TS 1000 C complete with link arm, screw accessories and installation template (Mounting plate not included)

_ TS 1000 C with hold-open link arm

for an adjustable opening angle between 700 and 1500

TS 1500

Surface-mounted rack and pinion door closer,

size 3-4 according to EN 1154

Product features

_ Variable closing force in two sizes achieved by simply turning the link arm’s power shoe:

‘Weak’ (closing force size 3 to EN 1154) for leaf widths up to 950 mm

‘Strong’ (closing force size 4 to EN 1154) for leaf widths up to 1100 mm

_ Closing speed adjustable, as is hydraulic latching action

_ Option: with hold-open link arm allowing the closer to hold doors open between 700 and 1500

Application range

_ For single-action doors up to 1100 mm

_ Can be used for right and left hand doors without adjustment

_ Standard type of installation: door mount, transom mounting is possible

Overhead rack and pinion door closer,

to EN 1154 A,size range 6 – 13 Product information for door closers The following information

concerning door closers for hinged leaf doors must be observed.

Failure to observe the information exonerates the manufacturer from liability or obligation.

1. Product information

and intended use

Door closers in terms of this definition shall be used to close hinged leaf doors again after they have been manually opened. The closing operation is performed

with adjustable hydraulic damping. The necessary closing force relative to the leaf widths is defined in EN 1154. The information from the manufacturers must be

observed in the case of areas of application other than conduit intended. Door closers shall be used on installed hinged-leaf doors made of metal, wood,

or UPVC and any combinations of these materials.

The mounting method and position are precisely prescribed for smoke and fire doors or other standardised selfclosing doors. Mounting

methods and positions other than conduit intended do not conform to the intended use.

Vertical, smoothly operating doors with correctly mounted door closers are prerequisites for the intended use of door closers. Mounting and

adjustment must be performed by qualified personnel according to the specifications from the manufacturer. Door closers

with greater closing forces must be used in the case of particularly unfavourable installation conditions (effects of wind).

Door closers with backcheck must be used, especially in the case of  hinged-leaf doors which are opened against wind

The backcheck contributes to protecting personnel, door elements, surrounding

walls and objects without restricting the door opening angle.

If, owing to the structural characteristics of the door, it is necessary to mount the door leaf to the frame at the door´s pivot axis, a stop which

restricts the maximum door opening angle of the door must be used.

Hinged leaf doors can only be held open at a specific position using additional special fittings or integrated construction

elements.With smoke and fire doors, the equipment must be approved by an inspector from the responsible

institute for structural engineering (documents supporting suitability must be observed).

Door closers are not suitable for the unprotected external installation into single-action doors and for use in environments with aggressive

corrosion-promoting air contents as well as extremely low or high temperatures.

Fitting boxes for floor springs must be protected against dirt penetration after their installation. If floor mounted door closers are exposed to water

penetration (e.g. damp locations or exterior doors without rain protection), the cavity between the cement box and door closer

housing must be filled with a suitable sealing compound.