Door closer with adjustable closing force:
The standards stipulate that the door closer size (closing force of the closer) must be selected
appropriate to the door width.
The next highest size must be selected if the structural (door height, door weight) or local
conditions (wind infl uence) makes this necessary.
The TS 4000 and variants covers several door closer sizes in one housing. These sizes can be
adjusted using an adjustment screw. The adjusted closing force is shown by a closing force indicator.
Cover caps for door closer For door closer TS 2000 V and TS 4000
cover caps are as follows available:
silver
_ dark bronze
_ white RAL 9016
_ polished brass
_ stainless steel
and further RAL colours on request.
TS 1000 C
Overhead door closer for single-leaf doors
Product features
_ Variable closing force in two sizes achieved by simply turning the link arm’s power shoe:
‘Weak’ (closing force size 2 to EN 1154) for leaf widths up to 850 mm
‘Strong’ (closing force size 3 to EN 1154) for leaf widths up to 950 mm
_ Increased closing force due to off set installation for leaf widths up to 1100 mm (size 4 to EN 1154)
_ Closing speed adjustable, as is hydraulic latching action
_ Option: with hold-open link arm allowing the closer to hold doors open between 700 and 150
Application range
_ For single-action doors up to 950 mm (1100 mm)
_ Can be used for right and left hand doors
without adjustment
_ For all common types of installation
Standard version/package
Overhead door closer TS 1000 C complete with link arm, screw accessories and installation template (Mounting plate not included)
_ TS 1000 C with hold-open link arm
for an adjustable opening angle between 700 and 1500
TS 1500
Surface-mounted rack and pinion door closer,
size 3-4 according to EN 1154
Product features
_ Variable closing force in two sizes achieved by simply turning the link arm’s power shoe:
‘Weak’ (closing force size 3 to EN 1154) for leaf widths up to 950 mm
‘Strong’ (closing force size 4 to EN 1154) for leaf widths up to 1100 mm
_ Closing speed adjustable, as is hydraulic latching action
_ Option: with hold-open link arm allowing the closer to hold doors open between 700 and 1500
Application range
_ For single-action doors up to 1100 mm
_ Can be used for right and left hand doors without adjustment
_ Standard type of installation: door mount, transom mounting is possible
Overhead rack and pinion door closer,
to EN 1154 A,size range 6 – 13 Product information for door closers The following information
concerning door closers for hinged leaf doors must be observed.
Failure to observe the information exonerates the manufacturer from liability or obligation.
1. Product information
and intended use
Door closers in terms of this definition shall be used to close hinged leaf doors again after they have been manually opened. The closing operation is performed
with adjustable hydraulic damping. The necessary closing force relative to the leaf widths is defined in EN 1154. The information from the manufacturers must be
observed in the case of areas of application other than conduit intended. Door closers shall be used on installed hinged-leaf doors made of metal, wood,
or UPVC and any combinations of these materials.
The mounting method and position are precisely prescribed for smoke and fire doors or other standardised selfclosing doors. Mounting
methods and positions other than conduit intended do not conform to the intended use.
Vertical, smoothly operating doors with correctly mounted door closers are prerequisites for the intended use of door closers. Mounting and
adjustment must be performed by qualified personnel according to the specifications from the manufacturer. Door closers
with greater closing forces must be used in the case of particularly unfavourable installation conditions (effects of wind).
Door closers with backcheck must be used, especially in the case of hinged-leaf doors which are opened against wind
The backcheck contributes to protecting personnel, door elements, surrounding
walls and objects without restricting the door opening angle.
If, owing to the structural characteristics of the door, it is necessary to mount the door leaf to the frame at the door´s pivot axis, a stop which
restricts the maximum door opening angle of the door must be used.
Hinged leaf doors can only be held open at a specific position using additional special fittings or integrated construction
elements.With smoke and fire doors, the equipment must be approved by an inspector from the responsible
institute for structural engineering (documents supporting suitability must be observed).
Door closers are not suitable for the unprotected external installation into single-action doors and for use in environments with aggressive
corrosion-promoting air contents as well as extremely low or high temperatures.
Fitting boxes for floor springs must be protected against dirt penetration after their installation. If floor mounted door closers are exposed to water
penetration (e.g. damp locations or exterior doors without rain protection), the cavity between the cement box and door closer
housing must be filled with a suitable sealing compound.